Standard Testing Sieves ASTM Specification E-11
|
|
Nominal Dimensions, Permissible Variations for Wire Cloth of Standard Test Sieves Standard Series
|
|
|
|
Sieve Designation
|
Norminal Sieve Opening
inch (c)
|
Permissible Variation of Average Opening from the Standard Sieve Designation
|
Opening Dimension Exceeded by not more than 5% of the openings
|
Maximum Individual Opening
|
Nominal Diameter
mm (a)
|
|
Standard(b)
|
Alternative
|
|
125mm
|
5"
|
5
|
±3.70mm
|
130.0mm
|
130.9mm
|
8
|
|
106mm
|
4.24"
|
4.24
|
±3.20mm
|
110.2mm
|
111.1mm
|
6.3
|
|
100mm (d)
|
4"
|
4
|
±3.00mm
|
104.0mm
|
104.8mm
|
6.3
|
|
90mm
|
3.5"
|
3.5
|
±2.70mm
|
93.6mm
|
94.4mm
|
6.3
|
|
75mm
|
3"
|
3
|
±2.20mm
|
78.1mm
|
78.7mm
|
6.3
|
|
63mm
|
2.5"
|
2.5
|
±1.90mm
|
65.6mm
|
66.2mm
|
5.6
|
|
53mm
|
2.5"
|
2.12
|
±1.60mm
|
55.2mm
|
55.7mm
|
5
|
|
50mm (d)
|
2"
|
2
|
±1.50mm
|
52.1mm
|
52.6mm
|
5
|
|
45mm
|
1.75"
|
1.75
|
±1.40mm
|
46.9mm
|
47.4mm
|
4.5
|
|
37.5mm
|
1.5"
|
1.5
|
±1.10mm
|
39.1mm
|
39.5mm
|
4.5
|
|
31.5mm
|
1.25"
|
1.25
|
±1.00mm
|
32.9mm
|
33.2mm
|
4
|
|
26.5mm
|
1.06"
|
1.06
|
±0.800mm
|
27.7mm
|
28.0mm
|
3.55
|
|
25.0mm
|
1.00"
|
1
|
±0.800mm
|
26.1mm
|
26.4mm
|
3.55
|
|
22.4mm
|
0.875"
|
0.875
|
±0.700mm
|
23.4mm
|
23.7mm
|
3.55
|
|
19.0mm
|
0.75"
|
0.75
|
±0.600mm
|
19.9mm
|
20.1mm
|
3.15
|
|
16.0mm
|
0.625"
|
0.625
|
±0.500mm
|
16.7mm
|
17.0mm
|
3.15
|
|
13.2mm
|
0.530"
|
0.53
|
±0.410mm
|
13.83mm
|
14.05mm
|
2.8
|
|
12.5mm (d)
|
0.5"
|
0.5
|
±0.390mm
|
13.10mm
|
13.31mm
|
2.5
|
|
11.2mm
|
7.0625"
|
0.438
|
±0.350mm
|
11.75mm
|
11.94mm
|
2.5
|
|
9.5mm
|
0.375"
|
0.375
|
±0.300mm
|
9.97mm
|
10.16mm
|
2.24
|
|
8.0mm
|
0.3125"
|
0.312
|
±0.250mm
|
8.41mm
|
8.58mm
|
2
|
|
6.7mm
|
0.265"
|
0.265
|
±0.210mm
|
7.05mm
|
7.20mm
|
1.8
|
|
6.3mm (d)
|
0.25"
|
0.25
|
±0.200mm
|
6.64mm
|
6.78mm
|
1.8
|
|
5.6mm
|
No. 3.5 (e)
|
0.223
|
±0.180mm
|
5.90mm
|
6.04mm
|
1.6
|
|
4.75mm
|
No. 4
|
0.187
|
±0.150mm
|
5.02mm
|
5.146mm
|
1.6
|
|
4.0mm
|
No. 5
|
0.157
|
±0.130mm
|
4.23mm
|
4.35mm
|
1.4
|
|
3.35mm
|
No. 6
|
0.132
|
±0.110mm
|
3.55mm
|
3.66mm
|
1.25
|
|
2.8mm
|
No. 7
|
0.11
|
±0.095mm
|
2.975mm
|
3.070mm
|
1.12
|
|
2.36mm
|
No. 8
|
0.0937
|
±0.080mm
|
2.515mm
|
2.600mm
|
1
|
|
2.0mm
|
No. 10
|
0.0787
|
±0.070mm
|
2.135mm
|
2.215mm
|
0.9
|
|
1.7mm
|
No. 12
|
0.0661
|
±0.060mm
|
1.820mm
|
1.890mm
|
0.8
|
|
1.4mm
|
No. 14
|
0.0555
|
±0.050mm
|
1.505mm
|
1.565mm
|
0.71
|
|
1.18mm
|
No. 16
|
0.0469
|
±0.045mm
|
1.270mm
|
1.330mm
|
0.63
|
|
1.0mm
|
No. 18
|
0.0394
|
±0040mm
|
1.083mm
|
1.135mm
|
0.56
|
|
850µm (d)
|
No. 20
|
0.0331
|
±35µm
|
925µm
|
970µm
|
0.5
|
|
710µm
|
No. 25
|
0.0278
|
±30µm
|
775µm
|
815µm
|
0.45
|
|
600µm
|
No. 30
|
0.0234
|
±25µm
|
660µm
|
695µm
|
0.4
|
|
500µm
|
No. 35
|
0.0197
|
±20µm
|
550µm
|
585µm
|
0.315
|
|
425µm
|
No. 40
|
0.0165
|
±19µm
|
471µm
|
502µm
|
0.28
|
|
355µm
|
No. 45
|
0.0139
|
±16µm
|
396µm
|
425µm
|
0.224
|
|
300µm
|
No. 50
|
0.0117
|
±14µm
|
337µm
|
363µm
|
0.2
|
|
250µm
|
No. 60
|
0.0098
|
±12µm
|
283µm
|
306µm
|
0.16
|
|
212µm
|
No. 70
|
0.0083
|
±10µm
|
242µm
|
263µm
|
0.14
|
|
180µm
|
No. 80
|
0.007
|
±9µm
|
207µm
|
227µm
|
0.125
|
|
150µm
|
No. 100
|
0.0059
|
±8µm
|
174µm
|
192µm
|
0.1
|
|
125µm
|
No. 120
|
0.0049
|
±7µm
|
147µm
|
163µm
|
0.09
|
|
106µm
|
No. 140
|
0.0041
|
±6µm
|
126µm
|
141µm
|
0.071
|
|
90µm
|
No. 170
|
0.0035
|
±5µm
|
108µm
|
122µm
|
0.063
|
|
75µm
|
No. 200
|
0.0029
|
±5µm
|
91µm
|
103µm
|
0.05
|
|
63µm
|
No. 230
|
0.0025
|
±4µm
|
77µm
|
89µm
|
0.045
|
|
53µm
|
No. 270
|
0.0021
|
±4µm
|
66µm
|
76µm
|
0.036
|
|
45µm
|
No. 325
|
0.0017
|
±3µm
|
57µm
|
66µm
|
0.032
|
|
38µm
|
No. 400
|
0.0015
|
±3µm
|
48µm
|
57µm
|
0.030
|
|
32µm
|
No. 450
|
0.0012
|
±3µm
|
42µm
|
50µm
|
0.028
|
|
25µm (d)
|
No. 500
|
0.001
|
±3µm
|
34µm
|
41µm
|
0.025
|
|
20µm (d)
|
No. 635
|
0.0008
|
±3µm
|
29µm
|
35µm
|
0.02
|
(a) The average diameter of the wires in the x and the y direction, measured separately, of any wire cloth shall not deviate from the nominal values by more than ±15%.
(b) These standard designations correspond to the values for the test sieve openings recommended by The International Organisation for Standardisation (ISO) Geneva, Switzerland, except where noted.
(c) Only approximately to the metric values in Column 1.
(d) These sieves are not in the standard series but they have been included because they are in common usage.
(e) these numbers (3.5 to 635) are the approximate number of openings per linear inch, but it is preferred that the sieve be identified by the standard designation in millimeters or micrometers.
(f) 1,000µm = 1mm
Back to ATM Test Sieves
|